| Model |
DH10-3025 |
DH10-3030 |
DH10-3040 |
DH10-3050 |
DH10-3060 |
DH10-3080 |
DH10-30100 |
| AC input |
Single-phase 220V ±10% (Frequency: 50Hz/60Hz) |
| Output voltage |
0-30V |
| Output current |
0-25A |
0-30A |
0-40A |
0-50A |
0-60A |
0-80A |
0-100A |
| Output power |
750W |
900W |
1200W |
1500W |
1800W |
2400W |
3000W |
| Power Supply Stability Rate |
Less than or equal to 0.1%+10mV |
| Load Stability Rate |
0.1%+30mV |
| Voltage stabilization accuracy |
Less than or equal to ±0.1%FS |
| Steady flow accuracy |
Less than or equal to ±0.1%FS |
| Ripple wave rms |
≤0.1%FS+10mV |
| Voltage setting accuracy |
±0.1%FS+10mV |
| Current setting accuracy |
±0.1%FS+10mA |
| Voltage read-back accuracy & resolution ratio |
5-digit display | Precision: ±0.1%FS + 3 digits (covering 10%–100% of rated value) | Resolution: 1mV |
| Current readback accuracy & resolution ratio |
5-digit display | Precision: ±0.1%FS + 3 digits | Resolution: 1mA |
Resolution: 10mA |
| Display mode |
Code-breaking screen display |
| Overvoltage protection output |
Enable O.V.P protection in the menu. The protection threshold can be set arbitrarily. The output will be turned off when protection is activated. |
| Overcurrent protection output |
Set the menu to O.I.P protection. The protection value can be customized. After protection, the output is disabled. |
| Overtemperature Protection |
Built-in O.T.P protection with a protection threshold of 85°C ±5% (radiator temperature). |
| Voltage Setting |
Menu settings, encoder knob input |
| Current Setting |
Menu settings, encoder knob input |
| Communication mode |
RS-485/RS-232 (supports Modbus and SCPI protocols) |
| Function |
Constant voltage/constant current, return-type current protection, memory mode, LIST sequence cycle, adjustable ON/OFF time, pulse width output, 9999 cycles, three preset voltage current settings (full-width models), button lock |
| Output polarity |
The positive (+) and negative (-) outputs can be grounded arbitrarily. |
| Heat dissipation method |
Air blast cooling |
| Operational environment |
Indoor interior design specifications: Temperature: 0°C to 40°C; Humidity: 10% to 85% RH |
| Storage Environment |
Temperature: -20°C to 70°C; Humidity: 10% to 90% RH |
| Note: All values are typical and may exceed these figures under different loads or other conditions. The accuracy is measured during load-side voltage detection; deviations between actual and rated values may occur due to temperature errors and component aging. |
| Note: FS stands for full scale range; the three digits indicate the last displayed value. |